PlasmaQuant MS Elite inductively coupled plasma mass spectrometer

PlasmaQuant MS Elite series inductively coupled plasma mass spectrometers

PlasmaQuant MS Elite are PlasmaQuant inductively coupled plasma mass spectrometers of MS series, with ultra-high sensitivity. These ICP-MS are the most sophisticated in the world, provided with an ion mirror, a pre-filter and a hich-accuracy quadrupole, which makes them supremely versatile and the highest performing ICP-MS globally. Ergonomic, easy-to-maintain, versatile instruments with low argon consumption are intended both for research, and for routine tasks. The spectrometers offer the highest sensitivity (above 1.5 billion pulse/sec/ppm), low detection limits, and minimum noise level.

Main advantages:

  • owing to Eco Plasma technology, twice less argon versus the peers is required to maintain stable plasma;
  • iCRC is an integrated collision reaction cell with special design for high-performance removal of interferences;
  • ReflexION is a patented hollow ion mirror with 90-degree reflection of the ion beam to ensure the supreme sensitivity;
  • HD Quadrupol – a dedicated quadrupole design ensures extremely low background signal;
  • ADD10 – a digital detecting system that ensures an 11-order linear dynamic range thanks to using a digital detector with automatic sensitivity tuning;
  • quadrupole maximum frequency – 3 MHz for perfect weight separation;
  • PlasmaQuant® MS Elite – research-grade ICP-MS with the supreme sensitivity, low detection limits and the lowest argon consumption on the market.

Performance parameters

Material of samples / application: Polymers and plastics : Foods, feeds : Geological rocks : Environmental facilities : Metallurgical materials : Semiconductor manufacturing materials : Biological materials : Pharmaceutical manufacturing materials : Precious metals : Seawater : Oil and petroleum products Analysis type: Multi-element Detection limit range: ppt – ppm Wavelength range, nm: No data Operating mass range, amu: 3-260 Sensitivity, million pulse/sec/ppm: Li - 150 : Be - 40 : In - 1500 : Th - 1000 : U - 1000 Background, pulses per second, m/z=5: 1 Wavelength resolution @ 200 nm, pm: Number of elements in a sample: 50+ Number of samples per day: 100–500+ Sample atomization type: Argon inductively coupled plasma Analysis of As, Se, Sb, Hg, Bi, Te, and other hydride-forming elements: Option TDS level, g/l: 250 Refitting with an automatic sample changer: Option Detector type: Mass spectrometer Background correction: Digital Monochromator type: No data Analysis type: — Radiation source: No data Dimensions (L × W × H), mm: 660 × 589 × 1131 Weight, kg: 170